Paper
6 October 2000 Remote test methods of optical cable short insert losses
Author Affiliations +
Proceedings Volume 4231, Advanced Optical Manufacturing and Testing Technology 2000; (2000) https://doi.org/10.1117/12.402843
Event: International Topical Symposium on Advanced Optical Manufacturing and Testing Technology, 2000, Chengdu, China
Abstract
During fiber optic communication lines restoration often appear optical cable short insert joint quality control needs. It is problem to measure of short cable insert fiber splice losses on long-haul optical communication lines. This problem is caused by limits of dynamic range and resolution of optical time domain reflectometer (OTDR). We present overview of ways of short cable insert optical power losses control on long- haul optical communication lines. Theoretical and experimental proof some of this methods is considered. Numerical results are represented. A good agreement of theoretically predicted and experimental values is demonstrated.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vladimir A. Burdin and Anton V. Bourdine "Remote test methods of optical cable short insert losses", Proc. SPIE 4231, Advanced Optical Manufacturing and Testing Technology 2000, (6 October 2000); https://doi.org/10.1117/12.402843