Paper
25 October 2001 Investigation of multilayer planar waveguide parameters using m-line spectroscopy method for biological liquid sensing
Elzbieta Augusciuk, Marcin Roszko, Andrzej W. Domanski
Author Affiliations +
Proceedings Volume 4597, Biophotonics Instrumentation and Analysis; (2001) https://doi.org/10.1117/12.446651
Event: International Symposium on Photonics and Applications, 2001, Singapore, Singapore
Abstract
A generalized m-line spectroscopy enables an evaluation of the parameters (the refractive index, n and the thickness, W) of sub-guiding films deposited on a planar waveguide. The method is based on a coupling of a laser beam with a prism coupler and studying of light distribution of the beam decoupled by the same prism. Additionally to the beam spot reflected geometrically from the prism base the light distribution takes a form of discrete lines - m-modes. This image can be observed but only for some discrete values of the coupling angles. The refractive index, n and thickness, W of the waveguide are evaluated by the numerical solution of the dispersion equation with a set of the coupling angles. A sub-guiding film (not reaching the guiding effect) when deposited on the existing planar waveguide influences the present guiding system and effects its guiding properties. From the previous and actual coupling angles the thin film parameters can be evaluated. In the paper an application of the generalized m-line spectroscopy to biological samples is presented. Some initial measurements reveal an effect of the presence of the films on the coupling angles of the structures. The presence of glucose has been revealed in secretions of patients suffering diabetes. Testing of its presence with proposed method can be performed with a trace amount of the patient secretion.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Elzbieta Augusciuk, Marcin Roszko, and Andrzej W. Domanski "Investigation of multilayer planar waveguide parameters using m-line spectroscopy method for biological liquid sensing", Proc. SPIE 4597, Biophotonics Instrumentation and Analysis, (25 October 2001); https://doi.org/10.1117/12.446651
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Waveguides

Refractive index

Prisms

Glucose

Spectroscopy

Planar waveguides

Wave propagation

Back to Top