26 October 2004 Aspects of x-ray microtomography equipment design
Graham R. Davis, James C. Elliott
Author Affiliations +
Abstract
We have developed a high definition X-ray microtomography scanner using time-delay integration CCD readout mode, whereby the camera is moved through the X-ray “shadow” during simultaneous readout. This method eliminates ring artefacts in the reconstructed image and allows the recorded image to be larger than the CCD itself. To maximise dynamic range, the reflective coated scintillator was lens coupled (two back-to-back 50mm f1.2 camera lenses). Equivalent X-ray photons per pixel were derived from noise measurements in specimen-absent projections. This was typically 600,000 for a 10 second exposure (90kV, 200μA, 25 cm source to camera). To quantify relay lens efficiency, this was re-measured at aperture settings from f1.2 to f11. The results closely fitted a model based on two noise sources (one from finite X-ray photons and one from finite light photons per X-ray photon), yielding an efficiency of 60% at f1.2. Although higher efficiency is desirable, this is a good compromise that avoids CCD saturation. This suggests that when using the more efficient direct fibre-optic coupling, a reflective scintillator coating may be undesirable, as the marginal increase in efficiency would not justify any loss of resolution or dynamic range. Correction for beam hardening is currently carried out using a 7 step Al wedge to measure experimental attenuation vs theoretical attenuation for monochromatic radiation. We intend to modify this method to improve accuracy in a more diverse range of materials. Dishing artefacts were decreased further by using a moving X-ray aperture to reduce scattered radiation.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Graham R. Davis and James C. Elliott "Aspects of x-ray microtomography equipment design", Proc. SPIE 5535, Developments in X-Ray Tomography IV, (26 October 2004); https://doi.org/10.1117/12.556311
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Signal to noise ratio

Photons

Signal attenuation

Cameras

Sensors

Charge-coupled devices

RELATED CONTENT

Evaluation of a gamma camera system for the RITS 6...
Proceedings of SPIE (August 27 2015)
Key components for artifact free micro CT and nano CT...
Proceedings of SPIE (September 02 2010)
CT detector evaluation with complex random backgrounds
Proceedings of SPIE (March 12 2012)
Quantitative x-ray microtomography with a conventional source
Proceedings of SPIE (September 02 2010)
Soft X Ray And XUV Imaging With A Charge Coupled...
Proceedings of SPIE (January 01 1981)
EPIC pn CCD camera onboard XMM Newton an update...
Proceedings of SPIE (August 18 2005)

Back to Top