Paper
8 March 2011 Plaque characterization in ex vivo MRI evaluated by dense 3D correspondence with histology
Arna van Engelen, Marleen de Bruijne, Stefan Klein, Hence Verhagen, Harald Groen, Jolanda Wentzel, Aad van der Lugt, Wiro Niessen
Author Affiliations +
Abstract
Automatic quantification of carotid artery plaque composition is important in the development of methods that distinguish vulnerable from stable plaques. MRI has shown to be capable of imaging different components noninvasively. We present a new plaque classification method which uses 3D registration of histology data with ex vivo MRI data, using non-rigid registration, both for training and evaluation. This is more objective than previously presented methods, as it eliminates selection bias that is introduced when 2D MRI slices are manually matched to histological slices before evaluation. Histological slices of human atherosclerotic plaques were manually segmented into necrotic core, fibrous tissue and calcification. Classification of these three components was voxelwise evaluated. As features the intensity, gradient magnitude and Laplacian in four MRI sequences after different degrees of Gaussian smoothing, and the distances to the lumen and the outer vessel wall, were used. Performance of linear and quadratic discriminant classifiers for different combinations of features was evaluated. Best accuracy (72.5 ± 7.7%) was reached with the linear classifier when all features were used. Although this was only a minor improvement to the accuracy of a classifier that only included the intensities and distance features (71.6 ± 7.9%), the difference was statistically significant (paired t-test, p<0.05). Good sensitivity and specificity for calcification was reached (83% and 95% respectively), however, differentiation between fibrous (sensitivity 85%, specificity 60%) and necrotic tissue (sensitivity 49%, specificity 89%) was more difficult.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arna van Engelen, Marleen de Bruijne, Stefan Klein, Hence Verhagen, Harald Groen, Jolanda Wentzel, Aad van der Lugt, and Wiro Niessen "Plaque characterization in ex vivo MRI evaluated by dense 3D correspondence with histology", Proc. SPIE 7963, Medical Imaging 2011: Computer-Aided Diagnosis, 796329 (8 March 2011); https://doi.org/10.1117/12.878007
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic resonance imaging

Tissues

Image segmentation

Image registration

Tissue optics

In vivo imaging

3D image processing

Back to Top