Paper
21 March 2016 Combined registration and motion correction of longitudinal retinal OCT data
Andrew Lang, Aaron Carass, Omar Al-Louzi, Pavan Bhargava, Sharon D. Solomon, Peter A. Calabresi, Jerry L. Prince
Author Affiliations +
Abstract
Optical coherence tomography (OCT) has become an important modality for examination of the eye. To measure layer thicknesses in the retina, automated segmentation algorithms are often used, producing accurate and reliable measurements. However, subtle changes over time are difficult to detect since the magnitude of the change can be very small. Thus, tracking disease progression over short periods of time is difficult. Additionally, unstable eye position and motion alter the consistency of these measurements, even in healthy eyes. Thus, both registration and motion correction are important for processing longitudinal data of a specific patient. In this work, we propose a method to jointly do registration and motion correction. Given two scans of the same patient, we initially extract blood vessel points from a fundus projection image generated on the OCT data and estimate point correspondences. Due to saccadic eye movements during the scan, motion is often very abrupt, producing a sparse set of large displacements between successive B-scan images. Thus, we use lasso regression to estimate the movement of each image. By iterating between this regression and a rigid point-based registration, we are able to simultaneously align and correct the data. With longitudinal data from 39 healthy control subjects, our method improves the registration accuracy by 43% compared to simple alignment to the fovea and 8% when using point-based registration only. We also show improved consistency of repeated total retina thickness measurements.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrew Lang, Aaron Carass, Omar Al-Louzi, Pavan Bhargava, Sharon D. Solomon, Peter A. Calabresi, and Jerry L. Prince "Combined registration and motion correction of longitudinal retinal OCT data", Proc. SPIE 9784, Medical Imaging 2016: Image Processing, 97840X (21 March 2016); https://doi.org/10.1117/12.2217157
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical coherence tomography

Image registration

Eye

Retina

Blood vessels

Image segmentation

Image processing

Back to Top