1.IntroductionThe use of green fluorescent protein (GFP) as a marker to visualize specific proteins inside living cells has revolutionized cell biology.1, 2 The genetic sequence-encoding GFP has been optimized to facilitate both its expression in mammalian cells,3, 4 as well as its photophysics for best use in elucidating the distribution and intracellular trafficking of genetically tagged proteins.5, 6, 7, 8, 9 The advent of spectral variants of GFP has extended the utility of this technology by enabling the detection of protein-protein interactions in vivo. Specific proteins can now be tagged with florescent proteins (FPs) that fluoresce in the blue, green, yellow, orange, or red region.10 In conjunction with basic light microscopy, many molecular interactions can be implied based on simple colocalization studies.11 This colocalization approach is however limited by the resolution of light microscopy (typically, ). More sophisticated imaging technologies, including spectral imaging,12 fluorescence lifetime imaging (FLIM),13, 14, 15 and imaging based on changes in fluorescence anisotropy,16, 17 are being applied to detect interactions between FP-tagged proteins at a resolution of . One such approach is to monitor Förster resonance energy transfer (FRET) between a protein tagged with a donor-FP and a putative binding partner labeled with an acceptor FP. FRET efficiency can be measured by monitoring reciprocal change in the intensity of emission from donor and acceptor fluorophores. More advanced and precise measurement of FRET efficiencies can be achieved by monitoring the change of fluorescence lifetime of the donor fluorophore. A high transfer efficiency is often interpreted as an indication of close proximity . Another approach, also based on FRET, is emerging as a method for dynamically monitoring the multimeric state of protein assemblies.17, 18, 19 In this method, fluorescence anisotropy is used to measure energy migration between proteins labeled with the same FP. High anisotropy is indicative of low FRET and vice versa. Furthermore, the amplitude of a drop in anisotropy encodes information on the number of fluorophores in a molecular complex that are participating in the energy migration. The accurate interpretation of biological FRET experiments utilizing complex quantitative imaging modalities, such as anisotropy analysis or FLIM, relies on an in-depth knowledge of the photophysics of the fluorophores being used. Specifically, for FLIM, it is important to know the lifetime of a fluorophore in the absence of acceptors, and it is also essential to appreciate any other factors that might alter its fluorescence lifetime in the course of an experiment.20, 21, 22 For anisotropy analysis, it is important to know the fundamental anisotropy of a fluorophore (primarily a function of the orientation of its absorption and emission dipoles), how rigidly the fluorophore is attached to a protein of interest and it is also useful to understand any other factors that might alter the orientation of its emission relative to its excitation.20, 21, 22 Furthermore, these sophisticated types of imaging experiments are often difficult to interpret if other endogenous fluorophores are present. Under these circumstances, measured fluorescence lifetimes or anisotropies will be a function of both the fluorophores of interest, as well as the contaminating fluorophores. Unfortunately contaminating fluorophores, like flavins, nicotinamides, porphyrins, etc., are almost always present in living biological samples. Two of the most popular spectral variant of GFP used for biological FRET studies are Cerulean,23 a blue emitting FP, and Venus,24 a yellow emitter. The crystal structure of both of these proteins have been reported.25, 26 Although the photophysics of GFP has been extensively studied,27, 28, 29, 30 this knowledge base may not universally apply to these spectral variants. Furthermore, it has long been suggested that in the FP family FRET might occur between an internal tryptophan and the FP fluorophore.31, 32, 33 If true, this could significantly alter fluorescent protein lifetime and anisotropy in a wavelength-dependent manner, and potentially complicate the interpretation of FRET between Cerulean and Venus. In this study, we characterize the lifetime and anisotropy of purified Cerulean and Venus and in so doing reveal: (i) Cerulean and to a lesser extent Venus fluorescence both decay as a double exponential, (ii) These fluorophores are rigidly fixed within their beta-barrel structure, and (iii) they both express efficient energy transfer between an internal tryptophan and their fluorophores upon UV excitation. Because the fluorophore within Cerulean and Venus are sequestered from the solvent/media due to their protein structure, we find they are resistant to dynamic quenching. We demonstrate how this can be exploited to remove the effects of endogenous fluorophores in these types of FRET experiments. 2.Materials and MethodsTris buffer (Trizma), Acrylamide (electrophoresis grade), flavin mononucleotide (FMN), and KI were from Sigma-Aldrich Inc., St. Louis, Missouri. 20X PBS, pH-7.5 was from AMRESCO®, Solon, Ohio. The water used for the analysis was deionized (from Millipore® deionizer unit). Both Cerulean and Venus were diluted in Tris, pH 8.5. In the iodide quenching studies with FMN PBS pH 7.5 was used as the buffer as fluorescence of FMN is sensitive to alkaline pH. 2.1.Purification of Cerulean and Venus2.1.1.Expression and purification of Cerulean and Venus proteins6x His-tagged Cerulean and Venus cloned into pRSET B (Invitrogen) and the recombinant proteins were expressed in BL21 (DE3) pLysS bacteria (Invitrogen). Bacteria were lysed, and proteins were purified using Ni-NTA Magnetic Agarose beads (Qiagen), according to the manufacturer’s instructions. The protein was concentrated by centrifugation using Centricon centrifugal filter devices (Millipore). To assess protein integrity and purity of samples 1.4 and of purified Cerulean and Venus were run on a 10% SDS PAGE gel (Bio-Rad) and Coomassie stained. For the Western blots, of Cerulean and Venus proteins were separated on a 10% SDS-PAGE gel under denaturing conditions. The proteins in the gel were transferred onto a polyvinylidine flouride (PVDF) membrane (Immobilon P, Millipore) by electrophoresis. The blot was blocked in a solution containing phosphate-buffered saline (pH 7.4, Invitrogen), 0.05% Tween 20 (Sigma) (PBST), and 5% BSA (ICN Biochemicals) for . The blot was probed with rabbit anti-GFP polyclonal antibody (ab6556, Abcam; 1:1000 dilution) in PBST and 5% BSA for at room temperature. The blot was washed in PBST and then probed with a mixture of a goat anti-rabbit HRP conjugated antibody (Pierce, 1:5000 dilution) and HRP-Conjugated Biotin antibody (Cell Signaling, 1:5000 dilution; for biotinlyated mass ladder) in PBST for . The blot was rinsed and washed as described earlier. Protein bands were visualized by chemiluminescence (SuperSignal West Dura Extended Duration Substrate Kit, Pierce) using a Kodak Image Station 4000R. Densitometry analysis of the protein bands were performed using the analysis software in Kodak Image Station 4000R. 2.2.Fluorescence StudiesVarian Cary Eclipse fluorescence spectrophotometer (Varian Inc.) was used for steady-state fluorescence measurements. We used broad range (UV-Visual) polarizers (Manual Polarizer Accessory, Varian Inc., Australia) for measurements in both the visible and ultraviolet regions. At , the polarization was , whereas in visible region the polarization was . The mathematical expression used to calculate anisotropy was where and are vertically excited–vertically emitted and vertically excited–horizontally emitted fluorescence components of the proteins and is the instrumental factor.21Time-resolved fluorescence measurements were carried out on FluoTime200 fluorometer (PicoQuant GmbH). This fluorometer is equipped with an ultrafast microchannel plate and is capable to well resolve subnanosecond decays. For studies in the UV region, the samples were excited with a picosecond-pulsed LED light source PLS-280, with bandwidth of , manufactured by PicoQuant GmBh. Full width at half maxima (FWHM) of the pulse was , and the repetition rate used for the measurements using the LED was . For visible region studies, (for Cerulean) or (for Venus) pulsed laser diodes LDH-PC-405 or LDH-PC-470 (PicoQuant GmBh) were used, respectively, in the low-power regime ( FWHM) with repetition rates. The laser diodes are routinely used to measure fluorescence decays and lifetimes within accuracy. The lifetime data were analyzed by FluoTime software, version 4.0 (PicoQuant GmbH). For lifetime measurements, a monochromator supported by long wave pass filter on the observation path was used. All the measurements for lifetime decay were performed using magic angle conditions. The decay was fitted with a multiexponential model using the expression where is the intensity at a time , is the amplitude of ’th component and is the lifetime of the ’th component.Time-resolved anisotropy decays were fitted to the multiexponential model using the expression where, is the anisotropy in time , is the amplitude of the ’th component and is the correlation time of the ’th component.All the studies were carried out in room temperature . The background from the buffer was of the signal, and the background from external quencher KI in buffer was subtracted from all the concerned measurements. 3.Results and DiscussionThe purity of Cerulean and Venus were accessed using Coomasie staining of the proteins and Western blot analysis (Fig. 1 ). The serial dilution of Cerulean and Venus (1.4 and ) reveals a strong band at (FP, arrowheads in Fig 1) and some minor contaminants (double-headed arrows, Fig 1). Densitometry analysis of the Coomassie staining [Fig. 1a] revealed that Cerulean was 97% pure and Venus was 90% pure. 3.1.Steady-State FluorescenceCerulean–Venus is an excellent donor acceptor pair, with selective donor excitation using the 405 or laser lines, and observation at (no signal from acceptor at this wavelength). This significantly simplifies the FRET measurements and its interpretation. The excitation and emission spectra of both proteins are presented in Fig. 2 . There is a significant increase in the excitation intensity in the UV region, at . Emission spectra did not change with excitation (data not shown), suggesting either an electronic transition in the chromophore or that excitation energy absorbed by other moieties (such as aromatic amino acids) are efficiently transferred to the chromophore. To study these possibilities further, we measured polarization spectra. Figure 3 shows steady-state excitation and emission polarization spectra of Cereluan, while Fig. 4 shows the same for Venus protein. Whereas the anisotropy values remain relatively constant within the emission spectra (b), the excitation anisotropies decrease significantly in shorter wavelengths (top panels). Such polarization dependences are common in (i) single fluorophore with different excited-state dipoles at higher electronic transition and (ii) a donor-acceptor system when excitation anisotropy is observed at acceptor emission. In fact, single-step energy transfer significantly affects anisotropy. 3.2.Time-Resolved FluorescenceNext, we measured fluorescence lifetimes of fluorescent proteins with UV excitation and with direct long-wavelength excitation at 405 and for Cerulean and Venus, respectively. The intensity decays of Cereluan and Venus fluorescent proteins with long-wavelength excitation, measured by time-correlated single-photon counting, are presented in Figs. 5 and 6 , respectively. One- and two-exponential fits to the experimental data are presented in Table 1 . For both proteins, the fluorescence intensity decays were best fitted using a two-exponent decay model, though single exponential fits with lifetimes of 3.18 and for Cereluan and Venus may in many cases be acceptable. Lifetimes were significantly longer with UV excitation. Furthermore, strong negative lifetime components of were observed (Table 1). This is a characteristic property of a process occurring in the excited state. A negative component in the intensity decay indicates that the fluorescent protein chromophore is receiving additional “pumping” after excitation. This is consistent with FRET occurring between the aromatic amino acids and the fluorescent protein chromophore. Table 1Multiexponential analysis of fluorescence intensity decays of Cerulean and Venus.
This is visualized in Figs. 7 and 8 for Cerulean and Venus respectively. Although the data were fitted for the whole decay, we present the fit only for the initial , in order to show the necessity of negative component to fit the decay. The short decay time (0.16 and for Cerulean and Venus, respectively) associated with the negative decay component shows that the energy transfer process is very efficient if we assume that the lifetime of unquenched tryptophan or tyrosine is . This explains the absence of a significant tryptophan emission. The low steady-state excitation anisotropy value for Cerulean (Fig. 3) and negative value for Venus (Fig. 4) observed with excitation of is consistent with significantly different near-orthogonal orientations for donor (Trp) and acceptor (fluorescent protein chromophore) transition moments. However, characterization of Trp donor profile was not an option due to presence of mild spectroscopic impurities (as seen in SDS-Page and Western Blot). Anisotropy decays of both proteins (Figs. 9 and 10 ) are similar, displaying high values of initial anisotropy and correlation times of (Table 2 ). The fits to these decays can be modestly improved using a decay model with a second correlation time. However, these second correlation times are on the order of a few nanoseconds and are most likely associated with the nonspherical shape of the protein than with chromophore internal mobility. The very high steady-state anisotropies observed as well as the relatively slow anisotropy decays measured indicates that the fluorescent protein chromophores in Cerulean and Venus are rigidly oriented within the protein structure and have little freedom for rotation. This attribute should encourage polarization studies using fluorescent proteins, because the local fluorophore mobility is a bottleneck in many rotational diffusion investigations. Table 2Anisotropy decay analyses of Cerulean and Venus emission.
3.3.Fluorescence Quenching StudyGFP fluorescence is known to be resistant to many quenching reagents. This is thought to arise from the GFP -barrel protein structure that physically surrounds and sequester the GFP fluorophore from water soluble factors.25, 26 We next wanted to determine if the -barrel structure of Cerulean and Venus would also protect their fluorophores from quenching reagents. We also wanted to determine if the high-efficiency energy transfer observed with UV excitation was also insensitive to external quenchers. First, we noted that with long-wavelength excitations, even high concentrations of acrylamide or potassium iodide (KI) in the solution do not change the emissions of Cereluan or Venus proteins (data not shown). This indicates that their chromophores are not readily accessible to these quenchers. Next, we used UV excitation to test if the tryptophan fluorophore is also protected by the -barrel structure. Figures 11 and 12 show the effect of acrylamide and/or KI presence on the UV-excited Cereluan and Venus proteins. There was little evidence for quenching of either Cerulean or Venus fluorescence. We conclude that the fluorescent protein chromophores as well as the tryptophan residue is effectively shielded from these quenchers. One can note that, in the presence of acrylamide, the emission spectrum of our purified Cerulean (and to a lesser extent Venus) was reduced at (Fig. 11). Presumably, tryptophan in a small fraction of denatured fluorescent proteins can be quenched. We decided to test if the unique protective nature of the fluorescent protein -barrel structure can be exploited to suppress background fluorescence in fluorescent protein experiments. We prepared the mixture of Cereluan or Venus proteins with flavin mononucleotide (FMN). Flavins are an abundant chemical moiety found in cells. A major obstacle to live-cell florescence imaging is that flavin fluorescence often masks the fluorescence of less abundant exogenous fluorophores experimentally introduced into cells. To illustrate this, a solution of either Cerulean (Fig. 13 ) or Venus (Fig. 14 ) and the flavin FMN were prepared and their emission spectra recorded. As expected, the strong FMN emission masked the fluorescent protein spectra in these mixtures. Addition of 0.35 Molar KI selectively quenched FMN to reveal the previously masked fluorescence protein spectra. To illustrate this effect, we prepared and imaged a microscopy slide with immobilized Venus protein (Fig. 15, star-shaped spot). Next, a drop of FMN solution was applied to the slide, primarily over the immobilized Venus. This led to fluorescence dominated by FMN. The star-shaped Venus spot could not be distinguished. Finally, we progressively added KI solution [Fig. 15b]. As FMN was selectively quenched, the fluorescent Venus protein spot was again revealed. 4.ConclusionsIn addition to excitation with visible light both, Cereluan and Venus fluorescent proteins can be efficiently excited in the UV region at wavelengths , where tryptophan and tyrosine are excited. Surprisingly, appreciable emission from these aromatic amino acids was not observed in the emission spectra of fluorescent proteins when excited with UV light . UV excitation is thought to be accompanied by a very efficient energy transfer from aromatic amino acids (presumably tryptophan and/or tyrosine) to the fluorescent protein chromophore because, under these conditions, a negative lifetime decay component (pumping) was observed in the fluorescence intensity decay. The lifetime associated with this lifetime decay component was . Assuming a nonquenched lifetime of tryptophan/tyrosine species of , one can calculate a transfer efficiency of . With such a high-energy-transfer efficiency, it is not surprising that the fluorescence spectra of tryptophan in fluorescent proteins cannot be measured accurately. Also, presence of trace amount of impurities in the sample (Fig. 1) contribute to the signal seen at the Trp emission region, making the interpretation even more complex. Furthermore, steady-state anisotropy measurements of the Cerulean or Venus fluorophore were only low with UV excitation, again indicating energy transfer between an aromatic amino acid and the fluorescent protein chromophore. Time-resolved fluorescence anisotropy decay analysis also revealed that the emission dipole orientation of the Cereluan and Venus chromophores are rigidly fixed in the protein structure. This conclusion is based on our inability to detect any local, subnanosecond decay component in time-resolved anisotropy measurements. The presence of trace impurities in the sample makes the interpretation of fluorescence decay from the internal tryptophan more complex. This prevented us from determining if the orientation of its emission dipole is also rigidly fixed. Nonetheless, the negative steady-state anisotropy observed with UV excitation of Venus, which contains only one tryptophan residue, strongly indicates energy transfer from tryptophan residues to the chromophore region. The excitation anisotropy (while acceptor emission was observed) value dropped for Cerulean, but still remained positive. This can be due to presence of two tryptophan residues in Cerulean. Both, tryptophan and the fluorescent protein chromophore are buried in the protein structure and not accessible to the external quenchers, acrylamide and/or KI. This is a unique advantage of fluorescent proteins over other probes. We have shown that quenchers can be used to selectively suppress nonspecific fluorescent background. In biological samples, such as cells or tissue, fluorescent background is a major obstacle in any fluorescence study, especially in those based on FRET. Our observation that the fluorescence of purified Venus is selectively spared while the fluorescence of FMN is almost completely quenched suggests that using KI solution in washing procedures will improve the ratio of fluorescent protein emission to background fluorescence. We understand that high concentrations of iodide will be toxic to the cell itself and thus cannot be used in live-cell imaging instantaneously. But this study proves the concept that using flavin quenchers can be a good strategy of improving signal-to-noise ratio in imaging experiments that use these fluorescent proteins. Use of other known quenchers of flavin, such as oxygen or reducing flavins in the cells, can be a potentially feasible future strategy. These simple experimental manipulations might be the key for allowing quantitative imaging of fluorescent proteins in cells with high background fluorescence (such as neurons) or for readily detecting the fluorescence emission of single fluorescent protein molecules by dramatically increasing the signal-to-noise ratio. AcknowledgmentsThis research was supported by the National Institutes of Health Project No. ZO1AA000452-01 to S.S.V., and by the Texas Emerging Technologies Fund Grant to Z. G. ReferencesJ. Lippincott-Schwartz, E. Snapp, and A. Kenworthy,
“Studying protein dynamics in living cells,”
Nat. Rev. Mol. Cell Biol., 2
(6), 444
–456
(2001). https://doi.org/10.1038/35073068 1471-0072 Google Scholar
J. Zhang, R. E. Campbell, A. Y. Ting, and R. Y. Tsien,
“Creating new fluorescent probes for cell biology,”
Nat. Rev. Mol. Cell Biol., 3
(12), 906
–918
(2002). https://doi.org/10.1038/nrm976 1471-0072 Google Scholar
A. Crameri, E. A. Whitehorn, E. Tate, and W. P. Stemmer,
“Improved green fluorescent protein by molecular evolution using DNA shuffling,”
Nat. Biotechnol., 14
(3), 315
–319
(1996). https://doi.org/10.1038/nbt0396-315 1087-0156 Google Scholar
R. Heim, D. C. Prasher, and R. Y. Tsien,
“Wavelength mutations and posttranslational autoxidation of green fluorescent protein,”
Proc. Natl. Acad. Sci. U.S.A., 91
(26), 12501
–12504
(1994). https://doi.org/10.1073/pnas.91.26.12501 0027-8424 Google Scholar
L. S. Barak, S. S. Ferguson, J. Zhang, C. Martenson, T. Meyer, and M. G. Caron,
“Internal trafficking and surface mobility of a functionally intact beta2-adrenergic receptor-green fluorescent protein conjugate,”
Mol. Pharmacol., 51
(2), 177
–184
(1997). 0026-895X Google Scholar
S. P. Dobson, C. Livingstone, G. W. Gould, and J. M. Tavare,
“Dynamics of insulin-stimulated translocation of GLUT4 in single living cells visualised using green fluorescent protein,”
FEBS Lett., 393
(2–3), 179
–184
(1996). https://doi.org/10.1016/0014-5793(96)00879-4 0014-5793 Google Scholar
T. Nakamura, K. Aoki, and M. Matsuda,
“Monitoring spatio-temporal regulation of Ras and Rho GTPase with GFP-based FRET probes,”
Methods, 37
(2), 146
–153
(2005). https://doi.org/10.1016/j.ymeth.2005.05.021 1046-2023 Google Scholar
M. L. Nonet,
“Visualization of synaptic specializations in live C. elegans with synaptic vesicle protein-GFP fusions,”
J. Neurosci. Methods, 89
(1), 33
–40
(1999). https://doi.org/10.1016/S0165-0270(99)00031-X 0165-0270 Google Scholar
D. Toomre, P. Keller, J. White, J. C. Olivo, and K. Simons,
“Dual-color visualization of trans-Golgi network to plasma membrane traffic along microtubules in living cells,”
J. Cell. Sci., 112
(Pt 1), 21
–33
(1999). 0021-9533 Google Scholar
N. C. Shaner, P. A. Steinbach, and R. Y. Tsien,
“A guide to choosing fluorescent proteins,”
Nat. Methods, 2
(12), 905
–909
(2005). https://doi.org/10.1038/nmeth819 1548-7091 Google Scholar
M. M. Falk and U. Lauf,
“High resolution, fluorescence deconvolution microscopy and tagging with the autofluorescent tracers CFP, GFP, and YFP to study the structural composition of gap junctions in living cells,”
Microsc. Res. Tech., 52
(3), 251
–262
(2001). https://doi.org/10.1002/1097-0029(20010201)52:3<251::AID-JEMT1011>3.0.CO;2-# 1059-910X Google Scholar
C. Thaler, S. V. Koushik, P. S. Blank, and S. S. Vogel,
“Quantitative multiphoton spectral imaging and its use for measuring resonance energy transfer,”
Biophys. J., 89
(4), 2736
–2749
(2005). https://doi.org/10.1529/biophysj.105.061853 0006-3495 Google Scholar
Y. Chen, J. D. Mills, and A. Periasamy,
“Protein localization in living cells and tissues using FRET and FLIM,”
Differentiation, 71
(9–10), 528
–541
(2003). https://doi.org/10.1111/j.1432-0436.2003.07109007.x 0301-4681 Google Scholar
A. G. Harpur, F. S. Wouters, and P. I. Bastiaens,
“Imaging FRET between spectrally similar GFP molecules in single cells,”
Nat. Biotechnol., 19
(2), 167
–169
(2001). https://doi.org/10.1038/84443 1087-0156 Google Scholar
F. S. Wouters and P. I. Bastiaens,
“Fluorescence lifetime imaging of receptor tyrosine kinase activity in cells,”
Curr. Biol., 9
(19), 1127
–1130
(1999). https://doi.org/10.1016/S0960-9822(99)80484-9 0960-9822 Google Scholar
A. H. Clayton, Q. S. Hanley, D. J. Arndt-Jovin, V. Subramaniam, and T. M. Jovin,
“Dynamic fluorescence anisotropy imaging microscopy in the frequency domain (rFLIM),”
Biophys. J., 83
(3), 1631
–1649
(2002). https://doi.org/10.1016/S0006-3495(02)73932-5 0006-3495 Google Scholar
I. Gautier,
“Homo-FRET microscopy in living cells to measure monomer-dimer transition of GFP-tagged proteins,”
Biophys. J., 80
(6), 3000
–3008
(2001). https://doi.org/10.1016/S0006-3495(01)76265-0 0006-3495 Google Scholar
D. S. Lidke,
“Imaging molecular interactions in cells by dynamic and static fluorescence anisotropy (rFLIM and emFRET),”
Biochem. Soc. Trans., 31
(Pt 5), 1020
–1027
(2003). https://doi.org/10.1042/BST0311020 0300-5127 Google Scholar
L. W. Runnels and S. F. Scarlata,
“Theory and application of fluorescence homotransfer to melittin oligomerization,”
Biophys. J., 69
(4), 1569
–1583
(1995). https://doi.org/10.1016/S0006-3495(95)80030-5 0006-3495 Google Scholar
D. M. Jameson, J. C. Croney, and P. D. Moens,
“Fluorescence: basic concepts, practical aspects, and some anecdotes,”
Methods Enzymol., 360 1
–43
(2003). https://doi.org/10.1016/S0076-6879(03)60105-9 0076-6879 Google Scholar
J. R. Lakowicz, Principless of Fluorescence Spectroscopy, Wiley-VCH, Weinheim
(1999). Google Scholar
B. Valeur, Molecular Fluorescence, Plenum, New York
(2002). Google Scholar
M. A. Rizzo, G. H. Springer, B. Granada, and D. W. Piston,
“An improved cyan fluorescent protein variant useful for FRET,”
Nat. Biotechnol., 22
(4), 445
–449
(2004). https://doi.org/10.1038/nbt945 1087-0156 Google Scholar
T. Nagai, K. Ibata, E. S. Park, M. Kubota, K. Mikoshiba, and A. Miyawaki,
“A variant of yellow fluorescent protein with fast and efficient maturation for cell-biological applications,”
Nat. Biotechnol., 20
(1), 87
–90
(2002). https://doi.org/10.1038/nbt0102-87 1087-0156 Google Scholar
A. Rekas, J. R. Alattia, T. Nagai, A. Miyawaki, and M. Ikura,
“Crystal structure of venus, a yellow fluorescent protein with improved maturation and reduced environmental sensitivity,”
J. Biol. Chem., 277
(52), 50573
–50578
(2002). https://doi.org/10.1074/jbc.M209524200 0021-9258 Google Scholar
G. D. Malo,
“X-ray structure of Cerulean GFP: a tryptophan-based chromophore useful for fluorescence lifetime imaging,”
Biochemistry, 46
(35), 9865
–9873
(2007). https://doi.org/10.1021/bi602664c 0006-2960 Google Scholar
S. T. Hess, E. D. Sheets, A. Wagenknecht-Wiesner, and A. A. Heikal,
“Quantitative analysis of the fluorescence properties of intrinsically fluorescent proteins in living cells,”
Biophys. J., 85
(4), 2566
–2580
(2003). https://doi.org/10.1016/S0006-3495(03)74679-7 0006-3495 Google Scholar
S. Inoue, O. Shimomura, M. Goda, M. Shribak, and P. T. Tran,
“Fluorescence polarization of green fluorescence protein,”
Proc. Natl. Acad. Sci. U.S.A., 99
(7), 4272
–4277
(2002). https://doi.org/10.1073/pnas.062065199 0027-8424 Google Scholar
G. H. Patterson, S. M. Knobel, W. D. Sharif, S. R. Kain, and D. W. Piston,
“Use of the green fluorescent protein and its mutants in quantitative fluorescence microscopy,”
Biophys. J., 73
(5), 2782
–2790
(1997). https://doi.org/10.1016/S0006-3495(97)78307-3 0006-3495 Google Scholar
K. Suhling,
“Imaging the environment of green fluorescent protein,”
Biophys. J., 83
(6), 3589
–3595
(2002). https://doi.org/10.1016/S0006-3495(02)75359-9 0006-3495 Google Scholar
A. F. Bell, D. Stoner-Ma, R. M. Wachter, and P. J. Tonge,
“Light-driven decarboxylation of wild-type green fluorescent protein,”
J. Am. Chem. Soc., 125
(23), 6919
–6926
(2003). https://doi.org/10.1021/ja034588w 0002-7863 Google Scholar
J. J. van Thor, A. J. Pierik, I. Nugteren-Roodzant, A. Xie, and K. J. Hellingwerf,
“Characterization of the photoconversion of green fluorescent protein with FTIR spectroscopy,”
Biochemistry, 37
(48), 16915
–16921
(1998). https://doi.org/10.1021/bi981170f 0006-2960 Google Scholar
A. Volkmer, V. Subramaniam, D. J. Birch, and T. M. Jovin,
“One- and two-photon excited fluorescence lifetimes and anisotropy decays of green fluorescent proteins,”
Biophys. J., 78
(3), 1589
–1598
(2000). https://doi.org/10.1016/S0006-3495(00)76711-7 0006-3495 Google Scholar
|